In many locations from chemistry laboratories to industrial facilities, to find a way to guarantee the protection of life and property towards a potential hearth hazard, extinguishing techniques are used in addition to detection and alarm methods. It can additionally be extremely necessary that the extinguishing techniques put in can be triggered by the hearth extinguishing control panel, in order to remove a attainable fire with early intervention.
In order to satisfy these needs, and with 35 years of sectoral knowledge and experience, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant performance of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing process to be started manually and remotely; and
to ensure that the extinguishing course of could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these devices are produced using surface-mount technology and are geared toward making the automation of the extinguishing system and fireplace and gasoline detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times considering the wants of the set up. In instances that require the combination of the extinguishing system with the clever addressable fireplace detection system, it offers options by way of the monitoring modules that even have a ‘supervised’ possibility.
Supervised monitoring modules play an important position in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a potential open or short circuit in the wiring between the contact monitoring modules and the peripheral techniques can cause disruption of the triggering, with doubtlessly important consequences. For this reason, when choosing monitoring modules, it must be taken into consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable hearth detection and alarm management panels are continuously communicating with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to monitor conditions corresponding to open circuits and short circuits which will occur within the system. เพรสเชอร์เกจคือ can be carried out within the hearth extinguishing installation, such because the management and monitoring of all valves that can interrupt the circulate of water, water move alarm switches, pressure swap, and electric or diesel fireplace pumps.
By including two contact monitoring modules to 2 separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be used to control errors and the opposite to regulate the fire situation, monitoring and management of the extinguishing system through an clever addressable fireplace detection and alarm system may be carried out successfully.
For more data, go to www.mavili.com.tr/en