In many locations from chemistry laboratories to industrial amenities, so as to guarantee the security of life and property towards a potential fireplace hazard, extinguishing techniques are used along with detection and alarm systems. It is also extraordinarily necessary that the extinguishing techniques installed may be triggered by the fire extinguishing control panel, in order to remove a attainable fireplace with early intervention.
In order to fulfill these needs, and with 35 years of sectoral knowledge and expertise, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel working in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant performance of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be began manually and remotely; and
to guarantee that the extinguishing course of may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced using surface-mount technology and are aimed toward making the automation of the extinguishing system and fireplace and fuel detection system excellent.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by always considering the needs of the installation. In instances that require the combination of the extinguishing system with the clever addressable fireplace detection system, it supplies options via the monitoring modules that even have a ‘supervised’ option.
Supervised monitoring modules play an important function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or short circuit in the wiring between the contact monitoring modules and the peripheral systems could cause disruption of the triggering, with potentially important penalties. For this purpose, when selecting monitoring modules, it must be taken under consideration that they’ve supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fireplace detection and alarm control panels are continually speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 standards, it makes it simpler to watch situations such as open circuits and quick circuits which will happen in the system. pressure gauge ลม may be carried out within the fireplace extinguishing set up, such as the control and monitoring of all valves that can interrupt the circulate of water, water move alarm switches, pressure swap, and electric or diesel fireplace pumps.
By including two contact monitoring modules to two separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be used to control errors and the opposite to manage the fire state of affairs, monitoring and management of the extinguishing system by way of an intelligent addressable fire detection and alarm system may be performed successfully.